BESKRIVELSE

Whether designing an inverter, optimizing a power supply, testing communication links, measuring across a current shunt resistor, debugging EMI or ESD issues, or trying to eliminate ground loops in your test setup, common mode interference has caused engineers to design, debug, evaluate, and optimize “blind.”

Revolutionary IsoVu™ technology uses optical communications and power-over-fiber for complete galvanic isolation. When combined with an oscilloscope equipped with the TekVPI interface, it is the first, and only, measurement system capable of accurately resolving high bandwidth, differential signals, in the presence of large common mode voltage with: The Tektronix TIVM Series IsoVu™ Measurement System offers a galvanically isolated measurement solution for accurately resolving high bandwidth, differential signals up to ±50 Vpk in the presence of large common mode voltages with the best in class common mode rejection performance across its bandwidth.

The TIVM Series (IsoVu) products can be used on most Tektronix oscilloscopes with the TekVPI interface and on MSO/DPO70K series oscilloscopes with the TCA-VPI50 adapter. IsoVu utilizes an electro-optic sensor that converts the electrical signal from the sensor tip cables to an optical signal, which electrically isolates the device-under-test from the oscilloscope. IsoVu incorporates four separate lasers, an optical sensor, five optical fibers, and sophisticated feedback and control techniques. The sensor head, which connects to the test point, has complete electrical isolation and is powered over one of the optical fibers (No batteries required).

SPESIFIKASJONER
Bandwidths from DC to 1 GHz
1 Million to 1 (120 dB) Common Mode Rejection up to 100 MHz
10,000 to 1 (80 dB) Common Mode Rejection at 1 GHz
2,000 V Common Mode Voltage
Up to ±50 V Differential (DC + pk AC)
Output Clamping
Safety Certified<br><br>
<strong>Applications</strong>
Half/Full Bridge designs using GaN, SiC, IGBTs
Floating Measurements
Power Converter Design
Power Device Evaluation
Switching Power Supply Design
Inverter Design
Motor Drive Design
Electronic Ballast Design
EMI
ESD
Current shunt measurements
Remote probing capability<br><br>
<strong>Ideal for the following measurements</strong>
Differential measurements in the following conditions:
– Complete galvanic isolation is required
– High common mode voltage
– High frequency common mode interference
– High frequency measurements
Measurements in high EMI environments
EMI compliance testing